Septic Tank Design

Value

Pre 285

Per 285

Daily flow

1080 gpd

420 gpd

Area of field

5191 sf

2100 sf

Pretreatment

2250 gallon

475 gallon

Treatment Capacity

0 gpd

500 gpd

Pump Tank

1000 gallon

750 gallon

Observed life span

15 + years

3 – 8 years


Let's consider one real life example:
Residence in Austin, TX 78734
5,164 sf residence with an Aerobic/drip system
Class II soils placed over fractured rock
Area known for groundwater problems

Determination of Design Flow, Q:
Pre 285:
0 - 1500 sf 2 BR
1500 – 1900 sf 3 BR
800 sf = additional BR
1900 sf = 3 Bedrooms
(5164 – 1900) / 800 = 4.08 additional bedrooms.
Must round up to 5 additional bedrooms.
Number of Bedrooms = 3 + 5 = 8 Bedrooms
Q = (B + 1) x 120 gpd (with a 20% credit for low flow fixtures)
Qpre-285 = (8 + 1) x 120 gpd = 1080 gpd.
Per 285:
Table III, says less than 5500 sf is 6 Bedrooms.
6 Bedrooms, Qper-285 = 420 gpd.

Determination of Field Area:
Pre 285:
No specific guidance on drip, but
Generally accepted Ra < 0.1 gpd /sf
A = Q / Ra = 1080 / 0.1 = 10800 sf
Per 285:
Fractured rock, Ra = 0.2 gpd / sf
A = Q / Ra = 420 / 0.2 = 2100 sf
Note: Area provided = 2600 sf

Sizing of Tanks:
Pre 285:
Q = 1080 gpd
Pretreatment = 1000 gallon single compartment tank
Treatment = 1250 gpd
Pump tank = 1000 gallon single compartment tank, minimum
Per 285:
Q = 420 gpd
Pretreatment = 475 gallon
Treatment = 500 gpd
Pump tank = 750 gallon

Let's consider another real life example:
Residence in Austin, TX 78734
5,164 sf residence with an Aerobic/drip system
House built on fractured rock
Area known for groundwater problems

Determination of Design Flow, Q:
Pre 285:
0 - 1500 sf 2 BR
1500 – 1900 sf 3 BR
800 sf = additional BR
1900 sf = 3 Bedrooms
(5164 – 1900) / 800 = 4.08 additional bedrooms.
Must round up to 5 additional bedrooms.
Number of Bedrooms = 3 + 5 = 8 Bedrooms
Q = (B + 1) x 120 gpd (with a 20% credit for low flow fixtures)
Qpre-285 = (8 + 1) x 120 gpd = 1080 gpd.
Per 285:
Table III, says less than 5500 sf is 6 Bedrooms.
6 Bedrooms, Qper-285 = 420 gpd.

Determination of Field Area:
Pre 285:
LPD, ET sizing due to the lack of soil.
A = 31000 (1+ 8) / (70 – 16.25) = 5191sf (in two alternating fields)
Per 285:
LPD, Fractured rock, Ra = 0.2 gpd / sf
Theoretically, A = Q / Ra = 420 / 0.2 = 2100 sf
Realistically, A = 2100*5/3 = 3500 sf.

Sizing of Tanks:
Pre 285:
Q = 1080 gpd
Pretreatment
1250 + 4(250) = 2250 gallon dual compartment tank
Pump tank = 1000 gallon single compartment tank, minimum
Per 285:
Q = 420 gpd
Pretreatment = 475 gallon
Treatment = 500 gpd
Pump tank = 750 gallon



Previous Article : Septic Tank System - - Next Article : Septic Cleaner

Featured Articles
Providing Quality Service...Guaranteed In the Greater Austin Area of Travis, Hays, Williamson, Burnet, & Bastrop Counties , Hudson Bend, Volente, Westlake Hills, Buda, Kyle, San Marcos, Florence, Brushy Creek, Leander, Misc Locations, Bell County.
Call (512) 338-1804 for fast, dependable service.
Unhappy With Your Septic System? Why do so many customers end up dissatisfied with their septic systems? We feel it starts with nobody asking or even considering the owner's opinion before...
Seller Says "Too Bad" Seller Says “Too Bad” After Homebuyers Find Rotting Septic Tank Under Plywood (From Pumper Magazine, October 23, 2018) A news organization in Cortland Manor,...
Pumping Frequencies The table below provides an estimate of pumping frequency in years, based on the size of the first tank in gallons, and the number of...
  • Drip Septic Systems Drip fields on a slope must be designed and installed to prevent drain-back. Otherwise, the lowest part of...
  • How To Take Care Of Your Septic System Guidelines for the successful use of your septic system: Don't flush dangerous and damaging substances into the...
  • Septic Repairs We're here because nobody else wants to handle other folks' waste, but somebody must. We do the...
  • Septic Service Are you having problems getting the septic service that you were promised and that you already paid for...
  • Septic Chamber On–site leaching chambers are successfully replacing gravel and pipe for leach field installations. Their lightweight construction allow for...